background image
Operation Guide 2782
1
MO040
7-EB
Getting Acquainted
Congratulations upon your selection of this CASIO watch. To get the most out
of your purchase, be sure to carefully read this manual and keep it on hand
for later reference when necessary.
Applications
The built-in sensors of this watch measure altitude, barometric pressure,
temperature and underwater depth. Measured values are then shown on the
display. Such features make this watch useful when hiking, mountain
climbing, skin diving, or snorkeling, or when engaging in other such outdoor
activities.
For a watch with the elapsed time bezel
Rotate the elapsed time bezel to align the
mark with the minute hand.
After that, the number of minutes that elapse is
indicated by how far the minute hand has moved
from
.
Elapsed time bezel
Warning!
· The measurement functions built into this watch are not intended for
taking measurements that require professional or industrial precision.
Values produced by this watch should be considered as reasonable
representations only.
· This watch is intended for use up to skin diving and snorkeling. Never
use this watch while scuba diving.
· Never operate the buttons of the watch while underwater.
· CASIO COMPUTER CO., LTD. assumes no responsibility for any loss,
or any claims by third parties that may arise through the use of this
watch.
About This Manual
· Button operations are indicated using the
letters shown in the illustration.
· Each section of this manual provides you with
the information you need to perform operations
in each mode. Further details and technical
information can be found in the "Reference"
section.
· Most of the display examples in this manual
show only the digital display, without the analog
hands, as shown in the lower illustration.
(Light)
Timekeeping Mode
Barometer/
Thermometer Mode
Depth Gauge Mode
Press B.
· From the Timekeeping Mode, you can press B to directly enter the
Barometer/Thermometer Mode or D to enter the Altimeter Mode. You can
also use B and D to switch between the Barometer/Thermometer Mode
and the Altimeter Mode.
General Guide
· The illustration below shows which buttons you need to press to navigate
between modes.
· In any mode, press L to illuminate the display.
Countdown
Timer Mode
Stopwatch Mode
C
Altimeter Mode
C
Press C.
Press D.
Alarm Mode
Hand Setting Mode
C
Press C.
C
C
Timekeeping
This watch features separate digital and analog
timekeeping. The procedures for setting the
digital time and analog time are different.
· Whenever you need to adjust both the digital
and the analog time settings, make sure you
adjust the digital setting first.
Digital Time and Date
Use the Timekeeping Mode to set and view a
digital display of the current time and date. When
setting the digital time, you can also configure
settings for the 12/24-hour format.
Hour : Minutes
PM indicator
Seconds
Month ­ Day
Day of week
To set the digital time and date
1. In the Timekeeping Mode, hold down A until the seconds start to flash,
which indicates the setting screen.
2. Press C to move the flashing in the sequence shown below to select other
settings.
Year
Seconds
Hour
Minutes
Day
Month
12/24-Hour
Format
4. Press A to exit the setting screen.
Note
· Resetting the seconds to
00 while the current count is in the range of 30 to
59 causes the minutes to be increased by 1. In the range of 00 to 29, the
seconds are reset to
00 without changing the minutes.
· With the 12-hour format, the P (PM) indicator appears on the display for
times in the range of noon to 11:59 p.m. and no indicator appears for times
in the range of midnight to 11:59 a.m.
Setting
Seconds
Hour, Minutes
12/24-Hour
format
Year, Month,
Day
Button Operations
Press D to reset the seconds to
00.
Use D (+) and B (­) to change the setting.
Use D to toggle between 12-hour (
12H)
and 24-hour (
24H) timekeeping.
Use D (+) and B (­) to change the setting.
Screen
3. When the setting you want to change is flashing, use D and/or B to
change it as described below.
· With the 24-hour format, times are displayed in the range of 0:00 to 23:59,
without any indicator.
· The 12-hour/24-hour timekeeping format you select in the Timekeeping
Mode is applied in all modes.
· The year can be set in the range of 2000 to 2039. The day of the week is
calculated automatically in accordance with the date you set.
· The watch's built-in full automatic calendar automatically makes allowances
for different month lengths and leap years. Once you set the date, there
should be no reason to change it except after you have the watch's battery
replaced.


background image
Operation Guide 2782
2
Setting the Analog Time
Perform the procedure below when the time indicated by the analog hands
does not match the time of the digital display.
To adjust the analog time
1. In the Timekeeping Mode, press C five times
to enter the Hand Setting Mode.
2. Hold down A until the current digital time
starts to flash, which indicates the analog time
setting screen.
3. Press D to advance the analog time setting
by 20 seconds.
· Holding down D advances the analog time setting at high speed.
· If you need to advance the analog time setting a long way, hold down
D until the time starts advancing at high speed, and then press B.
This locks the high-speed hand movement, so you can release the two
buttons. High-speed hand movement continues until you press any
button. It will also stop automatically after the time advances 12 hours
or if an alarm starts to sound.
4. Press A to exit the setting screen.
· To return to the Timekeeping Mode, press C.
ll
l
l
l
ll
ll
l
l l
l l l l
l
l l l l l
l
Barometer/Thermometer
This watch uses a pressure sensor to measure air pressure (barometric
pressure) and a temperature sensor to measure temperature.
· You can calibrate the temperature sensor and the pressure sensor if you
suspect that readings are incorrect.
To take barometric pressure and temperature readings
Pressing B in the the Timekeeping Mode or in the Altimeter Mode enters the
Barometer/Thermometer Mode and automatically starts taking barometric
pressure and temperature measurements.
l l
lll
ll
l
l l
lll
ll
l
Press B to
toggle between
screens.
History Graph and
Barometric Pressure
History graph
Temperature
Barometric
pressure
Temperature and
Barometric Pressure
· It can take up to four or five seconds for the barometric pressure reading to
appear after you enter the Barometer/Thermometer Mode.
· Barometric pressure is displayed in units of 1hPa (or 0.05 inHg).
· The displayed barometric pressure value changes to
xxxx hPa (or inHg) if
a measured barometric pressure falls outside the range of 600 hPa to 1100
hPa (17.70 inHg to 32.45 inHg). The barometric pressure value will be
displayed again as soon as the measured barometric pressure is within the
allowable range.
· Temperature is displayed in units of 0.1°C (or 0.2°F).
· The displayed temperature value changes to
xx. x °C (or °F) if a
measured temperature falls outside the range of ­10.0°C to 60.0°C (14.0°F
to 140.0°F). The temperature value will be displayed again as soon as the
measured temperature is within the allowable range.
· Some countries refer to the barometric pressure unit hecto-pascal (hPa) as
millibars (mb). It really makes no difference, because 1hPa = 1mb.
· See "Barometer and Thermometer Precautions" for important precautions.
Barometric Pressure History Graph
Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
The barometric pressure history graph contains points that show you the
changes in barometric pressure readings taken by the watch for up to the last
18 hours. The rightmost point on the graph is the latest reading. The relative
positions of the points on the graph indicate whether barometric pressure is
rising, falling, or holding relatively steady.
· Though you can configure the watch to display barometric pressure in units
of hPa or inHg, the history graph always uses hPa. This means that the
points plotted on the history graph are based on ±3hPa changes in
barometric pressure.
· No point is plotted on the graph whenever a measurement operation fails
due to sensor malfunction, low battery power, or any other reason.
Relatively steady (within ±3hPa)
Rising (rise greater than 3hPa)
Falling (fall greater than 3hPa)
· Barometric pressure measurement is disabled whenever you are
performing depth measurement in the Depth Gauge Mode. Because of this,
the graph plots of barometric pressure measurement operations that occur
during a depth measurement are skipped.
The following shows how to interpret the data that appears on the barometric
pressure history graph.
A rising graph generally means improving weather.
A falling graph generally means deteriorating weather.
About Barometric and Temperature Measurements
· Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, barometric pressure and temperature measurements are taken every
five seconds for the first two or three minutes.
· The
indicator above
BARO flashes while the watch is taking a
barometric pressure reading.
· The barometer automatically takes measurements every three hours
(starting from midnight), regardless of what mode you are in. The results of
these measurements are used for plotting points on the barometric
pressure history graph.
· You can also perform a barometric pressure and temperature measurement
at any time by pressing B in the Barometer/Thermometer Mode.
Barometer and Thermometer Precautions
· The pressure sensor built into this watch measures changes in air
pressure, which you can then apply to your own weather predictions. It is
not intended for use as a precision instrument in official weather prediction
or reporting applications.
· Sudden temperature changes can affect pressure sensor readings.
· Temperature measurements are affected by your body temperature (while
you are wearing the watch), direct sunlight, and moisture. To achieve a
more accurate temperature measurement, remove the watch from your
wrist, place it in a well ventilated location out of direct sunlight, and wipe all
moisture from the case. It takes approximately 20 to 30 minutes for the
case of the watch to reach the actual surrounding temperature.
· You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure. See "Changing the Barometric
Pressure and Temperature Units" for details.
· You can select either Celsius (°C) or Fahrenheit (°F) as the display unit for
the measured temperature value. See "Changing the Barometric Pressure
and Temperature Units" for details.
Altimeter
A built-in altimeter uses a pressure sensor to detect the current air pressure,
which is then used to estimate the current altitude. The watch is pre-
programmed with ISA (International Standard Atmosphere) preset values,
which are used to convert air pressure readings to altitude values. If you
preset a reference altitude, the watch will also calculate the current relative
altitude based on your preset value.
Important!
· This watch estimates altitude based on air pressure. This means that
altitude readings for the same location may vary if air pressure changes.
· This watch employs a semiconductor pressure sensor, which is affected by
temperature changes. Make sure that the watch is not being exposed to
temperature changes while you are taking altitude measurements.
· To avoid the effect of sudden temperature changes on measurement, wear
the watch so it is in direct contact with your wrist during measurement.
· Do not rely upon this watch for altitude measurements or perform button
operations while engaging in sports where there are sudden altitude
changes, while sky diving, hang gliding, or paragliding, or while riding a
gyrocopter, glider, or any other aircraft.
· Remember that the air inside of a commercial aircraft is pressurized.
Because of this, the readings produced by this watch will not match the
altitude readings announced or indicated by the flight crew.
How the Altimeter Works
With the Preset Values (No Reference Altitude)
· The watch measures the air pressure at your current location and uses the
built-in ISA values to convert it to the equivalent altitude.
With a Reference Altitude
· If you set a reference altitude, the watch
uses that value when calculating altitude
based on air pressure.
· To determine the height of a tall building,
set the reference altitude to 0 on the
ground floor. Note, however, that you may
not be able to get a good reading if the
building is pressurized or air-conditioned.
· When mountain climbing, you can set the
reference value in accordance with a
marker along the way or altitude
information from a map. After you do this,
the altitude readings produced by the
watch will be more accurate than they
would without a reference altitude.
400
B
A


background image
Operation Guide 2782
3
To take an altitude reading
Pressing D in the Timekeeping Mode or in the
Barometer/Thermometer Mode enters the
Altimeter Mode and automatically starts altitude
measurement.
· It can take up to four or five seconds for the
altitude reading to appear after you enter the
Altimeter Mode.
· The Altimeter Mode screen also displays the
current temperature. See "Barometer/
Thermometer" for more information.
· During the first two or three minutes after
entering the Altimeter Mode, the
indicator
flashes on the display and measurements are
taken every five seconds. After that, the
indicator stops flashing and remains on the
display as measurements are taken every two
minutes.
lll
ll
ll
l l l
Altitude
Temperature
· Pressing D causes the measurement operation to restart from the
beginning of the cycle described above.
· Altitude is displayed in units of 5 meters (20 feet).
· The measurement range for altitude is ­700 to 4,000 meters (­2,300 to
13,120 feet). The display range for altitude (include values based on the
reference altitude) is ­4,000 to 4,000 meters (­13,120 to 13,120 feet).
· An altitude reading may result in a negative value in cases when you have
a reference altitude value set or because of certain atmospheric conditions.
· The displayed altitude value changes to
xxxx meters (or feet) if a
measured altitude falls outside the measurement range. The altitude value
will be displayed again as soon as the measured altitude is within the
allowable range.
· You can change the unit of measurement for the displayed altitude values
between meters (m) and feet (ft). See "To change the altitude unit".
Setting a Reference Altitude
After you set a reference altitude, the watch adjusts its air-pressure-to-altitude
conversion calculation accordingly. The altitude measurements produced by
this watch are subject to error caused by changes in air pressure. Because of
this, we recommend that you update the reference altitude whenever one is
available during your climb.
To set a reference altitude
1. In the Altimeter Mode, hold down A until
OFF appears (flashing) or until the display
goes blank. This is the setting screen.
· Wait for four or five seconds before
performing step 2, below. If you don't wait,
there is the chance of setting value error.
· If the display went blank in step 1, the
current reference value will appear
(flashing) on the display after the four or five
seconds pass.
l l l l l l
ll
ll
ll
ll
ll
ll
l l
l l
· If
OFF or the current reference altitude value does not appear at this
time, press A to return to the Altimeter Mode screen, and perform step
1 again.
2. Press D (+) or B (­) to change the current reference altitude value by 5
meters (or 20 feet).
· You can set the reference altitude within the range of ­4,000 to 4,000
meters (­13,120 to 13,120 feet).
· Pressing D and B at the same time returns to
OFF(no reference
altitude), so the watch performs air pressure to altitude conversions
based on preset data only.
3. Press A to exit the setting screen.
Depth Gauge
The pressure sensor of the watch can also be used to perform underwater
depth measurement while skin diving or snorkeling. Depth readings are taken
every three seconds, and displayed as a value up to 30 meters (98 feet). You
can store the data of your last dive in log memory, including total time
submerged, maximum depth, and water temperature at the maximum depth
attained during your dive. You can view the log data of your last dive before
beginning a new dive.
Important!
· Never use this watch to measure depth while scuba diving.
· This watch is designed to start depth measurement and record data in
memory after a depth of 1 meter (4 feet) is reached. Because of this, the
explanations in this User's Guide uses the term "submerged" to refer to
any depth deeper than 1 meter, and the "on the surface" to refer to any
depth shallower than 1 meter.
· Leaving the watch in the Depth Gauge Mode while not in the water
consumes battery power. Exit the Depth Gauge Mode whenever you are
not using it.
· The measurement unit selected in the Altimeter Mode is also used in the
Depth Gauge Mode.
What is "a dive"?
A dive starts when you pass a depth of one meter (about four feet) while the
watch is in the Depth Gauge Mode. The dive ends when you are on the
surface and exit the Depth Gauge Mode. A dive does not end if you surface
but do not exit the Depth Gauge Mode.
Enter the Depth Gauge Mode.
Exit the Depth Gauge Mode.
Start of dive
Total time submerged: 1 minute 50 seconds
Maximum depth
20 sec.
30 sec.
1 min.
Depth = 1.0 m
(4 ft.)
End of dive
· Remember that the term "dive" as used in this manual refers to skin diving
or snorkeling only.
· The watch will start depth measurement automatically when the sensor
detects that your depth exceeds one meter (about four feet).
· Depth measurement stops automatically whenever your depth becomes
less than one meter (four feet).
· Depth measurement restarts whenever you re-submerge past one meter
(four feet). All data that is measured between the start of the dive and the
end of the dive is treated as part of the same dive, no matter how many
times you surface during the dive.
To perform depth measurement
1. Before beginning a dive, enter the
Timekeeping Mode and then press C to enter
the Depth Gauge Mode.
· It can take up to four or five seconds until
(or 0) appears on the display.
2. Enter the water and submerge past one meter
(four feet) to start the dive.
3. When you want to end the dive, return to the surface and then press C to
exit the Depth Gauge Mode.
· Exiting the Depth Gauge Mode causes the data accumulated during the
dive (time submerged, maximum depth attained, water temperature at
maximum depth) to be stored in log memory.
· The watch will not exit the Depth Gauge Mode if any value other than
(or 0) is displayed for the depth when you press C. If
(or 0) does not
appear on the display even though you are on the surface (depth of less
than 1 meter/4 feet), perform the procedure under "To manually reset the
reference depth to 0 meters (feet)".
· See "Log Data" for information about viewing dive data.
To view water temperature and maximum depth
In the Depth Gauge Mode, you can press D toggles the display between the
Elapsed Measurement Time/Current Depth and the Water Temperature/
Maximum Depth screens.
· If you do not perform any button operation for about five or six seconds
while the Water Temperature/Maximum Depth screen is on the display, the
watch will automatically return to the Elapsed Measurement Time/Current
Depth screen.
· Never operate the buttons of the watch while underwater.
Important!
Note the following important precautions whenever using the Depth Gauge
Mode.
Press D to
toggle between
screens.
Elapsed Measurement Time/
Current Depth Screen
Elapsed
measurement time
(hours, minutes,
seconds)
Water
temperature
Current
depth
Water Temperature/
Maximum Depth Screen
Maximum
depth
Before Skin Diving/Snorkeling
· Before beginning a dive, check to make sure that none of the
following marks are shown on the display.
BATTERY (indicating a weak battery)
RECOVER (indicating a weak battery)
Err (indicating sensor malfunction)
· Make sure that
(or 0) is displayed at your current depth.
· Make sure that the watch is set to the correct time of day.
· Check the glass, case and band for cracks or chips.
· Make sure that the band is fastened securely around your wrist.


background image
Operation Guide 2782
4
While Skin Diving/Snorkeling
· Check to make sure that timer operation and depth measurement are
being properly.
· Take care when skin diving/snorkeling near rocks or coral to avoid
scratching the watch.
After Skin Diving/Snorkeling
· To avoid corrosion, rinse your watch thoroughly with fresh water to
remove salt water, dirt, etc. (When possible, soak the watch in fresh
water overnight to make sure that all salt is removed.)
· When using a metal band, occasionally clean inside the gaps in the
band using a soft toothbrush and soapy water. Failure to do so can
result in corrosion of the timepiece, soiling of clothing or irritation to
sensitive skin.
Depth Gauge Mode Precautions
· After you enter the Depth Gauge Mode, the watch automatically takes a
reference pressure reading and sets the result a 0 meters (feet). This
means that before starting a dive, you should enter the Depth Gauge Mode
while at the water's surface, never while the watch is submerged.
· A major change in air temperature or other phenomena while you are using
the Depth Gauge Mode can cause the display to show a value other than 0
meters (feet) when you are at the surface of the water. If this happens, reset
the reference depth to 0 meters (feet). See "To manually reset the reference
depth to 0 meters (feet)" for more information.
· Depth values are displayed in units of 0.1 meter (or 1 foot).
·
(or 0)is displayed whenever your depth is less than one meter (four
feet).
· dEEP is displayed in place of the depth value whenever your depth is
greater than 30 meters (98 feet). If you continue to dive deeper after
dEEP
appears, xxxx will appear in place of the depth value. If xxxx remains on
the display after you surface, hold down C for three seconds to exit the
Depth Gauge Mode. If xxxx keeps appearing in place of the depth value, it
could mean that the sensor is malfunctioning. Take the watch to the place
where you purchased it or to some other CASIO retailer to have it checked.
· If the elapsed measurement time exceeds three hours, the watch will
automatically switch to the Timekeeping Mode and store the data for the
current dive into log memory.
· The progress beeper and auto-repeat timer alarm do not sound while the
watch is in the Depth Gauge Mode.
· The watch can take about five minutes to display the correct water
temperature when there is a great difference between air temperature and
water temperature, when there is a sudden change in water temperature,
etc.
Log Data
Exiting the Depth Gauge Mode after a dive causes the measured data to be
stored automatically into log memory. Stored data remains in log memory
until you start a new dive, which causes the existing data to be replaced with
the data of the new dive.
There is memory for a single log memory record, which includes the following
data.
Total Time Submerged: This value shows the cumulative amount of time
(hours, minutes, seconds) that you spend submerged at a depth of
one meter (four feet) or greater.
Maximum depth: This value shows the maximum depth you attained during
the dive.
Water temperature at maximum depth: This value shows the water
temperature at the maximum depth attained during the dive.
Perform the following steps to view the log data that is currently stored in
memory.
To view log data
1. While in the Timekeeping Mode, press C to enter the Depth Gauge Mode.
2. Press B to cycle through the data screens in the sequence shown below.
· If you do not perform any button operation for about five or six seconds
while a Log Data screen is on the display, the watch will automatically
return to the Depth Gauge Mode screen.
Maximum
depth
Water temperature at
maximum depth
Total time submerged
Press B.
Depth Gauge
Mode Screen
Log Data Screens
B
Log data
screen indicator
B
· You cannot view log memory data while a depth measurement operation
is in progress.
3. To exit the Depth Gauge Mode, press C.
To delete log memory data
1. While in the Timekeeping Mode, press C to enter the Depth Gauge Mode.
2. Press B to display the log memory data.
3. Hold down A for about two seconds until the log data is deleted and the
watch returns to the Depth Gauge Mode screen.
4. To exit the Depth Gauge Mode, press C.
Countdown Timer
You can set a countdown timer start time in the
range of 1 minute to 24 hours. An alarm sounds
when the countdown reaches zero. An auto-
repeat feature causes the countdown to restart
automatically when the end of a countdown is
reached, and a progress beeper signals the
progress of the countdown. All of this makes the
countdown timer a valuable tool for timing the
start of a yacht race.
· All of the operations in this section are
performed in the Countdown Timer Mode,
which you enter by pressing C.
Configuring the Countdown Timer
The following are the settings you should configure before actually using the
countdown timer.
· Countdown start time
· Auto-repeat on/off
· Progress beeper on/off
1/10 second
Seconds
Minutes
Hours
Countdown start time
You can set a countdown start time from 1 minute to 24 hours.
Auto-repeat
Whenever zero is reached, the watch beeps (Auto-repeat timer alarm) and
auto-repeat automatically restarts the countdown from the countdown start
time you set. Turning off auto-repeat causes the countdown to stop and the
countdown start time to appear on the display when the end of the countdown
is reached.
Progress Beeper
When the progress beeper is turned on, the watch beeps at minute 10, 5, 4,
3, 2, and 1, of the countdown, and at the second 50, 40, 30, 20, 10, 5, 4, 3, 2,
and 1 of the final minute of the countdown.
To set the countdown start time and auto-repeat on/off
1. In the Countdown Timer Mode, hold down A
until the hour setting of the countdown start
time starts to flash, which indicates the setting
screen.
2. Press C to move the flashing in the sequence
shown below to select other settings.
3. Perform the following operations, depending
on which setting is currently selected on the
display.
· While the hour or minute setting is flashing,
use D (+) or B (­) to change it.
· For a 24-hour countdown, set a start time of
0:00.
Auto-repeat
on/off
Hours
Minutes
ll
ll
l
l l
l l l l
l
ll
l l
l
l
l
ll
ll
ll
l
l
l l
l
Auto-repeat indicator
· While the auto-repeat setting (
ON or OFF) is flashing on the display,
press D to toggle auto-repeat on (
ON) and off (OFF).
4. Press A to exit the setting screen.
· The auto-repeat indicator (
) appears on the display while auto-repeat is
turned on.
To turn the progress beeper on and off
Pressing B while the countdown start time is on
the display or while a countdown timer operation
is in progress in the Countdown Timer Mode
toggles progress beeper operation on (
displayed) and off (
not displayed).
Progress beeper
on indicator


background image
Operation Guide 2782
5
To use the countdown timer
Press D while in the Countdown Timer Mode to start the countdown timer.
· When the countdown reaches zero, the alarm sounds for 10 seconds or
until you stop it by pressing any button.
· Press D while a countdown operation is in progress to pause it. Press D
again to resume the countdown.
· The countdown timer operation continues even if you exit the Countdown
Timer Mode.
· To completely stop a countdown operation, first pause it (by pressing D),
and then press B. This returns the countdown time to its starting value.
· If the countdown timer is running while you are using the Depth Gauge
Mode while diving, the alarm will sound when the end of the countdown is
reached. However, the following countdown timer beeper operations are
disabled during a Depth Gauge Mode dive.
Auto-repeat timer alarm
Progress beeper
· Frequent use of auto-repeat and the alarm can run down battery power.
Stopwatch
The stopwatch lets you measure elapsed time,
split times, and two finishes.
· The display range of the stopwatch is 23 hours,
59 minutes, 59.99 seconds.
· The stopwatch continues to run, restarting from
zero after it reaches its limit, until you stop it.
· The stopwatch measurement operation
continues even if you exit the Stopwatch Mode.
· Exiting the Stopwatch Mode while a split time is
frozen on the display clears the split time and
returns to elapsed time measurement.
· All of the operations in this section are
performed in the Stopwatch Mode, which you
enter by pressing C.
Hours Minutes
Seconds
1/100 second
To measure times with the stopwatch
J
J
J
Elapsed Time
DD
D
D
B
Start
Stop
Re-start
Stop
Clear
Split Time
DB
B
D
B
Start
Split
Split release
Stop
Clear
(SPL displayed)
Two Finishes
DB
D
B
B
Start
Split
Stop
Split release
Clear
JJ
JJ
J
JJ
J
First runner
finishes.
Display time
of first runner.
Display time of
second runner.
Second runner
finishes.
Alarms
You can set five independent daily alarms. When
an alarm is turned on, the alarm tone sounds
when the alarm time is reached.
You can also turn on an Hourly Time Signal that
causes the watch to beep twice every hour on the
hour.
· The alarm number (1 through 5) indicates an
alarm screen.
:00 is shown for the alarm time
when the Hourly Time Signal screen is on the
display.
· All of the operations in this section are
performed in the Alarm Mode, which you enter
by pressing C.
Alarm Time
(Hour : Minutes)
Alarm on indicator
Alarm number
Hourly time signal
on indicator
To set an alarm time
1. In the Alarm Mode, use D to scroll through
the alarm screens until the one whose time
you want to set is displayed.
ll
ll
l
l l
l l l l l
l
ll
Alarm
1
Hourly Time
Signal
Alarm
2
Alarm
5
Alarm
3
Alarm
4
3. Press C to move the flashing between the hour and minute settings.
4. While a setting is flashing, use D (+) and B (­) to change it.
· When setting the alarm time using the 12-hour format, take care to set
the time correctly as a.m. (no indicator) or p.m. (P indicator).
5. Press A to exit the setting screen.
Alarm Operation
The alarm sounds at the preset time for about 10 seconds (in all modes), or
until you stop it by pressing any button.
To test the alarm
In the Alarm Mode, hold down D to sound the alarm.
To turn an alarm and the Hourly Time Signal on and off
1. In the Alarm Mode, use D to select an alarm or the Hourly Time Signal.
2. When the alarm or the Hourly Time Signal you want to is selected, press
B to turn it on and off.
Indicates alarm is ON.
Indicates Hourly Time Signal is ON.
· The alarm on indicator (
) and the Hourly Time Signal on indicator ( )
are shown on the display in all modes while these functions are turned on.
· If any alarm is on, the alarm on indicator is shown on the display in all
modes.
Backlight
The backlight uses an EL (electro-luminescent)
panel that causes the entire display to glow for
easy reading in the dark. The watch's auto light
switch automatically turns on the backlight when
you angle the watch towards your face.
· The auto light switch must be turned on
(indicated by the auto light switch on indicator)
for it to operate.
· See "Backlight Precautions" for other important
information about using the backlight.
To turn on the backlight manually
Press L in any mode to illuminate the display for about two seconds.
· The above operation turns on the backlight regardless of the current auto
light switch setting.
Auto light switch on
indicator
About the Auto Light Switch
Turning on the auto light switch causes the backlight to turn on for about two
seconds, whenever you position your wrist as described below in any mode.
Moving the watch to a position that is parallel to the ground and then tilting
it towards you more than 40 degrees causes the backlight to turn on.
· Wear the watch on the outside of your left wrist.
Parallel to
ground
More than
40°
Warning!
· Always make sure you are in a safe place whenever you are reading
the display of the watch using the auto light switch. Be especially
careful when running or engaged in any other activity that can result
in accident or injury. Also take care that sudden illumination by the
auto light switch does not surprise or distract others around you.
· When you are wearing the watch, make sure that its auto light switch
is turned off before riding on a bicycle or operating a motorcycle or
any other motor vehicle. Sudden and unintended operation of the auto
light switch can create a distraction, which can result in a traffic
accident and serious personal injury.
To turn the auto light switch on and off
In any mode except while a setting is flashing on the display, hold down L for
about two seconds to toggle the auto light switch on (
displayed) or off (
not displayed).
· The auto light switch on indicator ( ) is on the display in all modes while
the auto light switch is turned on.
· The auto light switch will remain on for a maximum of about six hours. After
that, the auto light switch will turn off automatically in order to conserve
battery power.
· The auto light switch is always disabled, regardless of its on/off setting,
while the Hand Setting Mode setting screen is on the display.
· The backlight may not light right away if you raise the watch to your face
while a barometric pressure or altitude measurement operation is in
progress.
2. Hold down A until the hour digits of the alarm
time start to flash, which indicates the setting
screen.
· This automatically turns on the alarm.