Pickup device: 1/4", Effective pixels: 752 (H) x 582 (V)
Horizontal resolution: Over 520 TV lines
Lens: x22 zoom lens, f=3.6-79.2 mm (F1.6-3.8),
Electronic zoom and gearing, Zoom speed setting possible
Electronic zoom: 16 power (combined with optic zoom gives 352 power max)
Max zoom magnification setting possible, Vertical resolution ON/OFF setting
Autofocus: AUTO/MANUAL, AF area setting possible (3 step)
Iris control: AUTO/MANUAL, 1/2 EV steps
Synchronization method: Internal synchronization/Line lock, V phase adjustment possible
Lowest image illumination: 1.2 lx (F 1.6, AGC gain at maximum, COLOR mode)
0.06 lx (F 1.6, B/W mode)
0.04 lx (F1.6, x32 electronic sensitivity increased, COLOUR mode)
0.002 lx (F 1.6, x32 SENSE UP, B/W mode)
S/N: Over 48dB
Backlight compensation: Multi-spot evaluative metering
5 spot centerweighted average metering, 48 multi-spot metering
Day/Night: AUTO/COLOR/B/W settings available
Electric shutter:
· Fast shutter speed mode (SHORT);
1/50, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000
· Slow shutter speed mode (LONG); x1, x2, x4, x8, x16, x32
Electronic sensitivity boosting: AUTO/OFF, works with auto iris, Up to x32 max setting possible
White balance: ATW/AWC/MWB, AGC gain: OFF/-6/
±0/+6/+9/+12/+15 dB
Motion detector: ON/OFF, ON allows setting of detection patterns on a 48 zone screen for
6 motion settings (size, masking, sensitivity, zoom, interval, alarm sign)
Privacy masking: ON/OFF, max of 4 masked locations, Password lock possible
Alarm input/output (back panel control terminals): Alarm input: 1 (for external alarm switch)
Alarm output: 1 (for sending a signal to the system controller or an alarm
detection device such as a buzzer)
Mirror image effect: Horizontally (H), vertically (V), horizontally and vertically (HV)
Camera ID: ON/OFF, 16 characters
View settings: 9 (0-8) screen files can be established, and each file can set
7 capturing characteristics such as iris
Communications: Coaxial control, RS-485
Operational temperature/humidity: -10 - 50
°C/below 90 % RH
Power source: 24 V AC, 50 Hz/12-15 V DC, Power consumption: 4.5 W, Weight: 380 g
SERVICE MANUAL
COLOUR CCD Camera
VCC-ZM400P
(Product Code : 117 118 00)
(Europe)
FILE NO.
REFERENCE No. SM5310469
L5AD2/XE
NOTE : 1. Parts order must contain model number, part number, and description.
2. Substitute parts may be supplied as the service parts.
3. N. S. P. : Not available as service parts.
Design and specification are subject to change without notice.
The components designated by a symbol ( ! ) in this schematic diagram designates components whose value are of
special significance to product safety. Should any component designated by a symbol need to be replaced, use only the
part designated in the Parts List. Do not deviate from the resistance, wattage, and voltage ratings shown.
PRODUCT SAFETY NOTICE
CONTENTS
1. DISASSEMBLY AND
BOARD LOCATION ....................... 2
2. ADJUSTMENT ............................... 3
3. PARTS LIST ................................... 6
CIRCUIT DIAGRAM &
PRINTED WIRING BOARDS ........... C1
SPECIFICATIONS


background image
­ 2 ­
1. DISASSEMBLY AND BOARD LOCATION
1. Three screws 2 x 4
2. Cabinet back
3. Three screws 3 x 4
4. Cover top
5. Two screws 3 x 6
6. Cover mounting
7. Two screws 3 x 4
8. Cover bottom
9. Cabinet front
10. Two screws 2 x 3
11. Frame
12. Screw 2 x 3
13. Chassis front
14. Screw 2 x 3
15. Connector
16. Connector
17. FPC
18. Screw 2 x 3
19. Connector
20. CA4 board
21. Two screws 2 x 3
22. Screw 3 x 6
23. Screw 3 x 6
24. Screw 3 x 10
25. Terminal
26. CA5 board
27. Two screws 2 x 3
28. Two FPCs
29. Connector
30. CA2 board
31. Screw 2 x 3
32. Connector
CA1 board
CA3 board
CA2 board
CA4 board
CA5 board
33. CA3 board
34. Three screws 2 x 5
35. Chassis
36. Two screws 1.7 x 5
37. Screw 2 x 3
38. CA1 board


background image
­ 3 ­
2-3. TABLE FOR SERVICING TOOLS
Note: Adjustment commander relay jig (VHJ-0142) is for 100 V.
2-3-1. Computer screen during adjustment
2-4. Iris Adjustment
Adjustment location: VR202, VR203 (CA-2)
Measuring location: TP221 (CA-2)
Measuring equipment: Digital multi meter
Subject: No designation
Adjusting method:
1. Click the adjustment software installed from the personal
computer, and the adjustment window will be displayed.
2. Click the START.
3. Select the COLOR in the adjustment display.
4. Select the IRIS 1V in the adjustment display.
5. Turn the VR203 so that the voltage of TP221 is 1.0 V
± 0.1 V.
6. Select the IRIS 3V in the adjustment display.
7. Turn the VR202 so that the voltage of TP221 is 3.0 V
± 0.1 V.
2. ADJUSTMENT
2-1. ADJUSTMENT CONDITION
1. Use the 5,100K viewer for the subject.
2. Set the trigger signal of oscilloscope to VIDEO OUT, and
apply H sync unless specified.
3. Connect the video output to a video monitor with an input
impedance of 75
.
4. Ground test point is TP200 (CA-2).
5. Set the distance from the subject to about 60 cm and adjust
the camera position so that the picture frame size becomes
as shown below when performing the adjustment with the
gray scale chart (ITE gray scale chart/
= 0.45).
2-2. PREPARATION
1. Install the adjustment software (VHJ-0150) in a computer
running the Windows operating system.
2. Use the adjustment commander cable (VHJ-0143) to con-
nect the adjustment commander relay jig (VHJ-0142) and
CN204.
3. Use the adjustment commander relay jig (VHJ-0142) to con-
nect CN204 of side B in the CA-2 board and serial port (RS-
232C) of computer, and then turn on the power for the com-
puter, camera, and the jig.
VIDEO OUTPUT
Ref. No.
Name
Part code
J-1
J-2
J-3
VJ8-0007
VJ8-0009
Color viewer
Gray scale chart
Color bar chart
VJ8-0010
J-4
J-5
J-6
VHJ-0142
VHJ-0150
Adjustment commander relay jig
Calibration software
L: Distance from CS mount to pattern (mm)
H: Pattern height (mm)
f : Lens focal length (standard 12 mm)
h: Height (4.8 mm) of CCD imaging surface
Note : The video monitor should be an under-scan TV.
L =
x f ­ 12.5 mm
(H + h)2
H x h
L
CS mount surface
CCD camera
5,100 K viewer
H
VHJ-0139
Privacy masking chart
J-7
VHJ-0143
Adjustment commander cable
AGC
R GAIN
R HUE
B GAIN
B HUE
WDD
L5AD Series Adjustment
x
0
0
0
0
0
AUTO
ROM CLEAR
START
END
CLOSE
TRIG
INT
L-L
IRIS 1V
IRIS 3V
LENS T
AUTO
TELE
LENS X
LENS Y
0
0
TELE
POS1
POS2
R
B
STATUS
DAY/NIGHT
COLOR
B/W
AUTO


background image
­ 4 ­
2-5. Lens Tracking Adjustment
Adjustment location:
Measuring location:
Measuring equipment: Monitor display, siemens star chart
Subject: No designation
Adjusting method:
1. Select the LENS T in the adjustment display.
2. Set the siemens star chart at the position of 940 mm
± 10
mm so that it becomes center of the screen.
3. Click the AUTO button.
4. When AUTO ADJ. NG display, carry out the adjustment again.
2-6. Privacy Masking Compensation
Adjustment location:
Measuring location:
Measuring equipment: Monitor display, privacy masking chart
Subject: No designation
Adjusting method:
1. Set the privacy masking chart at the position of 940 mm
±
10 mm from the lens.
2. Select the TELE under the LENS T in the adjustment dis-
play. Adjust the field angle so that the center of the privacy
masking chart becomes center of the screen.
3. Operate the LENS X and LENS Y in the adjustment display.
Adjust so that masking is center of the screen.
4. Select the TELE under the LENS Y in the adjustment dis-
play. Confirm that masking is within the limit of the screen.
When the masking is out of the frame, carry out adjustment
again.
2-7. Frequency Adjustment (INT)
Adjustment location: CT252, CT202 (CA-2)
Measuring location: TP203, TP202 (CA-2)
Measuring equipment: Digital multi meter, Frequency counter
Subject: No designation
Adjusting method:
1. Click the adjustment software installed from the personal
computer, and the adjustment window will be displayed.
2. Click the START.
3. Select the TRIG, and select the INT by the
key of a
keyboard.
4. Adjust with TP203 to 17734475 Hz
± 50 Hz.
5. Adjust with CT202 so that the voltage of TP202 is 7.0 V
±
0.5 V.
2-8. Frequency Adjustment (L-L)
Adjustment location: CT201 (CA-2)
Measuring location: TP201 (CA-2)
Measuring equipment: Digital multi meter
Subject: No designation
Adjusting method:
1. Select the TRIG, and select the L-L by the
key of a
keyboard.
2. Adjust with CT201 so that the voltage of TP201 is 7.0 V
±
0.5 V.
3. Select the INT by the
key of a keyboard.
2-9. AGC Level Adjustment
Adjustment location: Computer screen
Measuring location: VIDEO OUT
Measuring equipment: Oscilloscope
Subject: Gray scale chart
Adjusting method:
1. Select the POS1 in the adjustment display, and project the
gray scale at the field angle of below figure.
2. Select the AGC in the adjustment display.
3. Use the computer's mouse to adjust the AGC in the adjust-
ment window so that the video out terminal is 750
± 10 mVp-p.
2-10. Hue and Chroma Adjustment
Adjustment location: Computer screen
Measuring location: VIDEO OUT
Measuring equipment: Oscilloscope, vectorscope
Subject: Color bar chart
1. Select POS2 in the adjustment display, and project the color
bar chart at the field angle of below figure.
2. Select the R and B in the adjustment display. Adjust by oper-
ating
key of a keyboard so that the white luminescent
spot is the center of the vectorscope.
3. Select the R GAIN, R HUE, B GAIN and B HUE in the ad-
justment display. Adjust by operating level scroll bar so that
the red and yellow luminescent spots are the size and po-
sition which are designated in the vectorscope.
4. Select the ROM CLEAR in the adjustment display.
siemens star chart
lens
VIDEO OUTPUT
10
35
µsec
940 mm
± 10 mm
camera
viewer


background image
­ 5 ­
2-11. CCD White Point Defect Detect Adjustment
Measuring location: VIDEO OUT
Measuring equipment: Monitor display
Adjustment method:
1. Shield light with a lens cap to provide dark condition.
2. Set the camera mode, and click the "AUTO" at the WDD on
the adjustment software.
3. After completing this adjustment, it comfirms that white point
can not be seen on the monitor display.
4. Click the End button.
CT201
TP221
CA-2 board (Side B)
VR203
TP200
CT252
VR202
TP201
TP203
CT202
TP202
45
µsec
R
YL
MG
Cy
G
B
75%
100%
cy
g
yl
mg
b
U
v
YL
R
W